The air conditioning system developed by our company adopts the combination of external circulation cooling water of shield machine and compressed cooling air to cool down the operating surface of the interval tunnel. On the basis of the traditional external circulation cooling and tunnel ventilation, an air conditioning system is installed on the shield machine to cool the tunnel ventilation airflow before entering the secondary fan system, so that the cooling air can be transferred from the outlet of the secondary ventilation system to the construction operation surface (pipe segment assembly area). The air outlet temperature of the secondary fan can reach 20°C, 10-12°C lower than the maximum temperature under normal temperature, which is enough to  effectively cool down the working area, and the ambient temperature is suitable for construction.
Working principle

Refrigeration main unit and heat preservation water tank are arranged on the first floor of the trolley, the size can be customized freely according to the existing space of the shield machine, and the relative position of the main machine, water pump and water tank can be flexibly modulated; the air cooler is placed on the second floor of the trolley and is connected in series with the air duct The size can be the same as the existing air duct of the trolley, and the air cooler can be placed by installing the air duct, which is completely not restricted by the narrow space on the second floor.

Refrigeration main unit cooling uses the original external circulating water of the trolley, and is divided into three links for the cooling water from the shield machine inlet pipe to the plate heat exchanger. The water consumption is small, the allowable inlet water temperature is high, and the original external water circulation of the shield construction increases The power of the water pump can meet the water demand of the refrigerator without adjustment, without additional cooling water circuit.

Product Features
Air conditioning cooling unit
It adopts high quality screw compressor and the 5:6 screw rotor design, whose capacity is 20%-30% higher than general compressors. It uses special compressor motor which is suitable for environmentally­ friendly refrigerants R134A, R407C and R410a. It has low failure rate, stable and reliable operation, and no fault running time: 50000-80000 hours. The products have obtained two international quality certifications of 1S09001 and 1S09002 and multinational patents in Europe and America.
Air cooling plant
The air cooling device of the tunnel air conditioning unit is designed and selected according to the air supply requirements of the secondary fan and the actual installation space of the shield machine. The product series can be customized with different air pipe diameters, DN400/DN600/DN800/DN1000 etc.

It is suitable for air conditioning cooling requirements of various small shield machines and large diameter shield units.


Technical Parameter
Model TRU250 TRU350 TRUS00
Motor Refrigerant R134a/R407c/R410a
Nominal Cooling Capacity kW 250 350 500
Power Consumption kW 57 86 123
Power Supply 380-415V/3ph/50-60Hz
Outlet Pipe Diameterin 3 3 4
Cooling Water Flow Rate (m'/h) 10月15日 20-25 30-35
Cooling Water Inlet Temperature(C) 25-40 25-40 25-40
Cooling Water Outlet Temperature(C) 31-46 31-46 31-46
Reference Unit Dimensions:L*W*H (mm) 3000*900*1800 3000*900*2000 3600*1400*2000
Reference Unit Weight (kg) 1680 1880 2730
Control

System

Protection Devices
Phase Reversal Protection,Phase Loss Protection.Overcurrent Protection,

Discharge Temperature Protection.High and Low Pressure Protection,

Low Temperature Protection.Water Flow Protection

Control Method SIEMENS PLC or remote control from a central control room
Energy Regulation (%) 0,25,50,75,100
Air Cooler Airflow Rate (m/h) 20000-40000 40000-60000 70000-90000
Reference Duct Diameter (mm) Dn600 Dn800 Dn1000
Outlet Temperature (C) 33-22 33-22 33-22
Unit Dimensions:L*W*H(mm) 3500*700*700 4000*800*800 5000*1200*1200
Reference Unit Weight (kg) 850 1055 1250

Remarks:

1.The tunnel air conditioning unit is a non-standard customized product. The above data is based on existing case product series and is for reference only.
2.The specific equipment model will be selected according to the actual operating conditions, and a design and selection proposal will be provided accordingly.

Application area
Water diversion, Sewage, Cable, Communication, Gas supply and other municipal utilities comprehensive pipeline projects.